Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 188
Filter
1.
Eur Heart J ; 45(18): 1613-1630, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38596850

ABSTRACT

BACKGROUND AND AIMS: Increasing data suggest that stress-related neural activity (SNA) is associated with subsequent major adverse cardiovascular events (MACE) and may represent a therapeutic target. Current evidence is exclusively based on populations from the U.S. and Asia where limited information about cardiovascular disease risk was available. This study sought to investigate whether SNA imaging has clinical value in a well-characterized cohort of cardiovascular patients in Europe. METHODS: In this single-centre study, a total of 963 patients (mean age 58.4 ± 16.1 years, 40.7% female) with known cardiovascular status, ranging from 'at-risk' to manifest disease, and without active cancer underwent 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography between 1 January 2005 and 31 August 2019. Stress-related neural activity was assessed with validated methods and relations between SNA and MACE (non-fatal stroke, non-fatal myocardial infarction, coronary revascularization, and cardiovascular death) or all-cause mortality by time-to-event analysis. RESULTS: Over a maximum follow-up of 17 years, 118 individuals (12.3%) experienced MACE, and 270 (28.0%) died. In univariate analyses, SNA significantly correlated with an increased risk of MACE (sub-distribution hazard ratio 1.52, 95% CI 1.05-2.19; P = .026) or death (hazard ratio 2.49, 95% CI 1.96-3.17; P < .001). In multivariable analyses, the association between SNA imaging and MACE was lost when details of the cardiovascular status were added to the models. Conversely, the relationship between SNA imaging and all-cause mortality persisted after multivariable adjustments. CONCLUSIONS: In a European patient cohort where cardiovascular status is known, SNA imaging is a robust and independent predictor of all-cause mortality, but its prognostic value for MACE is less evident. Further studies should define specific patient populations that might profit from SNA imaging.


Subject(s)
Positron Emission Tomography Computed Tomography , Humans , Female , Male , Middle Aged , Prognosis , Positron Emission Tomography Computed Tomography/methods , Aged , Europe/epidemiology , Cardiovascular Diseases/mortality , Brain/diagnostic imaging , Fluorodeoxyglucose F18 , Radiopharmaceuticals , Heart/diagnostic imaging
2.
Article in English | MEDLINE | ID: mdl-38683812

ABSTRACT

INTRODUCTION: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is characterized by progressive myocardial dysfunction and associated with an increased risk of major cardiovascular events. AIMS: To determine right heart strain (ventricular and atrial global longitudinal strain (RVGLS and RAGLS)) in patients with definite ARVC and its association with adverse events during follow-up. METHODS: RVGLS and RAGLS were analysed in focused right heart apical views from 70 patients using TomTec ImageArena and association with a composite endpoint (sustained ventricular arrhythmia and cardiovascular death) was determined. RESULTS: Over a median follow-up duration of 4.9 years, 26 (37%) patients met the endpoint. RVGLS was significantly impaired in the event group (-11.5 [-13.3 - -10.2]%) versus the no-event group (-15.8 [-17.1 - -14.5]%, P < 0.001), and so was RAGLS (22.8 [21.4 - 27.4]% vs. 31.5 [25.1 - 39.6]%, respectively, P < 0.001). In Cox regression, RVGLS (HR 1.36, P < 0.001) and RAGLS (HR 0.92, P = 0.002) were associated with higher risk of adverse events. In multivariable Cox regression models, RVGLS and RAGLS remained independent of and were incremental to age, gender, and conventional RV parameters, and model fit was improved when RVGLS and RAGLS were applied together rather than alone. CONCLUSIONS: RVGLS and RAGLS are more impaired in patients with adverse events and associated with adverse events independent of age, gender, and conventional RV parameters. When RVGLS and RAGLS are applied together, prediction models are improved suggesting that right heart strain may form part of the echocardiographic routine protocol in patients with ARVC.

3.
Front Cardiovasc Med ; 10: 1252872, 2023.
Article in English | MEDLINE | ID: mdl-37745112

ABSTRACT

Introduction: This study aims at exploring biventricular remodelling and its implications for outcome in a representative patient cohort with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). Methods and results: Pre-interventional echocardiographic examinations of 100 patients with severe AS undergoing TAVI were assessed by speckle tracking echocardiography of both ventricles. Association with mortality was determined for right ventricular global longitudinal strain (RVGLS), RV free wall strain (RVFWS) and left ventricular global longitudinal strain (LVGLS). During a median follow-up of 1,367 [959-2,123] days, 33 patients (33%) died. RVGLS was lower in non-survivors [-13.9% (-16.4 to -12.9)] than survivors [-17.1% (-20.2 to -15.2); P = 0.001]. In contrast, LVGLS as well as the conventional parameters LV ejection fraction (LVEF) and RV fractional area change (RVFAC) did not differ (P = ns). Kaplan-Meier analyses indicated a reduced survival probability when RVGLS was below the -14.6% cutpoint (P < 0.001). Lower RVGLS was associated with higher mortality [HR 1.13 (95% CI 1.04-1.23); P = 0.003] independent of LVGLS, LVEF, RVFAC, and EuroSCORE II. Addition of RVGLS clearly improved the fitness of bivariable and multivariable models including LVGLS, LVEF, RVFAC, and EuroSCORE II with potential incremental value for mortality prediction. In contrast, LVGLS, LVEF, and RVFAC were not associated with mortality. Discussion: In patients with severe AS undergoing TAVI, RVGLS but not LVGLS was reduced in non-survivors compared to survivors, differentiated non-survivors from survivors, was independently associated with mortality, and exhibited potential incremental value for outcome prediction. RVGLS appears to be more suitable than LVGLS for risk stratification in AS and timely valve replacement.

4.
JACC Case Rep ; 17: 101900, 2023 Jul 05.
Article in English | MEDLINE | ID: mdl-37496718

ABSTRACT

A 62-year-old man experienced embolization of a patent foramen ovale (PFO) occlusion device in the pulmonary artery. The device was successfully retrieved using "puncture to loop" technique, without the need of specific materials. This is a challenging retrieval situation, confirming the feasibility and flexibility of the technique. (Level of Difficulty: Advanced.).

5.
J Clin Med ; 12(11)2023 May 26.
Article in English | MEDLINE | ID: mdl-37297892

ABSTRACT

AIMS: Association of two-(2D) and three-dimensional (3D) left atrial strain (LAS) and low-voltage area (LVA) with recurrence of atrial fibrillation (AF) after pulmonary vein isolation (PVI) was assessed. METHODS AND RESULTS: 3D LAS, 2D LAS, and LVA were obtained in 93 consecutive patients undergoing PVI and recurrence of AF was analyzed prospectively. AF recurred in 12 patients (13%). The 3D left atrial reservoir strain (LARS) and pump strain (LAPS) were lower in patients with recurrent AF than without (p = 0.008 and p = 0.009, respectively). In univariable Cox regression, 3D LARS or LAPS were associated with recurrent AF (LARS: HR = 0.89 (0.81-0.99), p = 0.025; LAPS: HR = 1.40 (1.02-1.92), p = 0.040), while other values were not. Association of 3D LARS or LAPS with recurrent AF was independent of age, body mass index, arterial hypertension, left ventricular ejection fraction, and end-diastolic volume index and left atrial volume index in multivariable models. Kaplan-Meier curves revealed that patients with 3D LAPS < -5.9% did not exhibit recurrent AF, while those >-5.9% had a significant risk of recurrent AF. CONCLUSIONS: 3D LARS and LAPS were associated with recurrent AF after PVI. Association of 3D LAS was independent of relevant clinical and echocardiographic parameters and improved their predictive value. Hence, they may be applied for outcome prediction in patients undergoing PVI.

6.
ERJ Open Res ; 9(2)2023 Mar.
Article in English | MEDLINE | ID: mdl-37057079

ABSTRACT

Background: COPD may predispose to symptomatic pulmonary hypertension at high altitude. We investigated haemodynamic changes in lowlanders with COPD ascending to 3100 m and evaluated whether preventive acetazolamide treatment would attenuate the altitude-induced increase in pulmonary artery pressure (PAP). Methods: In this randomised, placebo-controlled, double-blind, parallel-group trial, patients with COPD Global Initiative for Chronic Obstructive Lung Disease grades 2-3 who were living <800 m and had peripheral oxygen saturation (S pO2 ) >92% and arterial carbon dioxide tension <6 kPa were randomised to receive either acetazolamide (125-250 mg·day-1) or placebo capsules, starting 24 h before ascent from 760 m and during a 2-day stay at 3100 m. Echocardiography, pulse oximetry and clinical assessments were performed at 760 m and after the first night at 3100 m. Primary outcome was PAP assessed by tricuspid regurgitation pressure gradient (TRPG). Results: 112 patients (68% men, mean±sd age 59±8 years, forced expiratory volume in 1 s (FEV1) 61±12% pred, S pO2 95±2%) were included. Mean±sd TRPG increased from 22±7 to 30±10 mmHg in 54 patients allocated to placebo and from 20±5 to 24±7 mmHg in 58 patients allocated to acetazolamide (both p<0.05) resulting in a mean (95% CI) treatment effect of -5 (-9 to -1) mmHg (p=0.015). In patients assigned to placebo at 760/3100 m, mean±sd S pO2 was 95±2%/88±3%; in the acetazolamide group, the respective values were 94±2%/90±3% (both p<0.05), resulting in a treatment effect of +2 (1 to 3)% (p=0.001). Conclusions: In lowlanders with COPD travelling to 3100 m, preventive acetazolamide treatment attenuated the altitude-induced rise in PAP and improved oxygenation.

7.
JACC Cardiovasc Imaging ; 16(3): 332-341, 2023 03.
Article in English | MEDLINE | ID: mdl-36889849

ABSTRACT

BACKGROUND: Left ventricular ejection fraction (LVEF) demonstrates limited prognostic value for post-transcatheter aortic valve replacement (TAVR) outcomes. Evidence regarding the potential role of left ventricular global longitudinal strain (LV-GLS) in this setting is inconsistent. OBJECTIVES: The aim of this systematic review and meta-analysis of aggregated data was to evaluate the prognostic value of preprocedural LV-GLS for post-TAVR-related morbidity and mortality. METHODS: The authors searched PubMed, Embase, and Web of Science for studies investigating the association between preprocedural 2-dimensional speckle-tracking-derived LV-GLS and post-TAVR clinical outcomes. An inversely weighted random effects meta-analysis was adopted to investigate the association between LV-GLS vs primary (ie, all-cause mortality) and secondary (ie, major cardiovascular events [MACE]) post-TAVR outcomes. RESULTS: Of the 1,130 identified records, 12 were eligible, all of which had a low-to-moderate risk of bias (Newcastle-Ottawa scale). On average, 2,049 patients demonstrated preserved LVEF (52.6% ± 1.7%), but impaired LV-GLS (-13.6% ± 0.6%). Patients with a lower LV-GLS had a higher all-cause mortality (pooled HR: 2.01; 95% CI: 1.59-2.55) and MACE (pooled odds ratio [OR]: 1.26; 95% CI: 1.08-1.47) risk compared with patients with higher LV-GLS. In addition, each percentage point decrease of LV-GLS (ie, toward 0%) was associated with an increased mortality (HR: 1.06; 95% CI: 1.04-1.08) and MACE risk (OR: 1.08; 95% CI: 1.01-1.15). CONCLUSIONS: Preprocedural LV-GLS was significantly associated with post-TAVR morbidity and mortality. This suggests a potential clinically important role of pre-TAVR evaluation of LV-GLS for risk stratification of patients with severe aortic stenosis. (Prognostic value of left ventricular global longitudinal strain in patients with aortic stenosis undergoing Transcatheter Aortic Valve Implantation: a meta-analysis; CRD42021289626).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Dysfunction, Left , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Ventricular Function, Left , Prognosis , Stroke Volume , Global Longitudinal Strain , Retrospective Studies , Predictive Value of Tests , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery
8.
J Clin Med ; 12(3)2023 Jan 24.
Article in English | MEDLINE | ID: mdl-36769561

ABSTRACT

Cardiocutaneous syndrome (CCS) is often caused by genetic variants in desmoplakin (DSP) in the presence of thick calluses on the hands and soles of the feet (palmoplantar keratoderma) in combination with arrhythmogenic cardiomyopathy. In this case report, we describe a 58-year-old man presenting with a history of cardiomyopathy with recurrent sustained ventricular tachycardia and palmoplantar keratosis. The cardiological evaluation showed biventricular cardiomyopathy, and repeated genetic testing identified a novel DSP variant. Repeated genetic testingis clinically meaningful in patients with a high probability of a specific inherited cardiac disease, such as CCS, particularly if molecular screening has been performed in the pre-NGS era with an incomplete NGS panel or outdated technology as presented in this case report.

11.
J Clin Med ; 11(24)2022 Dec 19.
Article in English | MEDLINE | ID: mdl-36556128

ABSTRACT

Arrhythmogenic Right Ventricular Cardiomyopathy (ARVC) is a hereditary condition that can cause sudden cardiac death in young, frequently athletic individuals under the age of 35 due to malignant arrhythmias. Competitive and endurance exercise may hasten the onset and progression of ARVC, leading to right ventricular dysfunction and potentially fatal ventricular arrhythmias earlier in life. In this article, we present a novel, pathogenic, early truncating heterozygous variant in the PKP2 gene that causes biventricular arrhythmogenic cardiomyopathy and affects a family, of which the only member with the positive phenotype is a competitive endurance athlete.

12.
Int J Cardiol ; 368: 86-93, 2022 12 01.
Article in English | MEDLINE | ID: mdl-35970442

ABSTRACT

AIMS: This study aimed at investigating whether tissue Doppler imaging (TDI) is associated with adverse events in arrhythmogenic right ventricular cardiomyopathy (ARVC). METHODS AND RESULTS: Transthoracic echocardiography was performed in 72 patients with definite (n = 63) or borderline (n = 9) ARVC diagnosed according to the 2010 Task Force Criteria and included in the prospective Zurich ARVC registry. Myocardial peak systolic tissue velocity (S') was measured by TDI at lateral tricuspid (tricuspid S'), medial mitral (septal S'), and lateral mitral annulus (lateral S'). Association of echocardiographic parameters with outcome was assessed by univariable Cox regression. During a median follow-up of 4.9 ± 2.6 years, 6 (8.3%) patients died of cardiovascular cause or received heart transplantation and 21 (29.2%) patients developed sustained ventricular arrhythmia. Tricuspid, septal, and lateral S' were lower in patients who died (p = 0.001; p < 0.001; p = 0.008; respectively), while tricuspid and septal S' were lower in those with ventricular arrhythmia (p = 0.001; p = 0.008; respectively). There was a significant association of tricuspid, septal, and lateral S' with mortality (HR = 1.61, p = 0.011; HR = 2.15, p = 0.007; HR = 1.67, p = 0.017; respectively), while tricuspid and septal S' were associated with ventricular arrhythmia (HR = 1.20, p = 0.022; HR = 1.37, p = 0.004; respectively). Kaplan-Meier analyses demonstrated a higher freedom from mortality with tricuspid S' >8 cm/s (p = 0.001) and from ventricular arrhythmia with S' >10.5 cm/s (p = 0.021). CONCLUSIONS: This study demonstrates that TDI provides information on the ARVC phenotype, is associated with adverse events in ARVC patients, and differentiates between patients with and without adverse events.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Arrhythmogenic Right Ventricular Dysplasia/diagnostic imaging , Echocardiography , Echocardiography, Doppler/methods , Humans , Prospective Studies , Systole
13.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Article in English | MEDLINE | ID: mdl-35920768

ABSTRACT

The retrograde valve-crossing of a stenotic aortic valve is a crucial step in the transcatheter aortic valve implantation procedure. In addition to being time-consuming and associated with an increased stroke risk, inappropriate valve-crossing may cause devastating complications. This tutorial review summarizes systematic and detailed techniques to cross the aortic valve. First, the main challenges in retrograde valve-crossing are depicted. Next, a step-by-step guidance on valve-crossing is provided, along with an in-depth description of the three-dimensional anatomy under a two-dimensional fluoroscopy view. Finally, modified techniques for different anatomies are described.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Algorithms , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Fluoroscopy , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
15.
J Card Surg ; 37(10): 3396-3402, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35842798

ABSTRACT

We report the case of a 78-year-old female with Sapien 3 transcatheter heart valve implantation in the transcaval approach. In this setting, we describe the step-by-step management and technique of the transcaval transcatheter aortic valve implantation.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Female , Humans , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
16.
Eur Heart J Cardiovasc Imaging ; 23(7): 970-978, 2022 06 21.
Article in English | MEDLINE | ID: mdl-35511038

ABSTRACT

AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is characterized by progressive fibro-fatty infiltration of the myocardium and associated with adverse cardiovascular (CV) events. This study aims to examine right atrial (RA) deformation in ARVC and understand its association with CV outcomes. METHODS AND RESULTS: RA strain was determined in 50 patients with definite ARVC, compared with a matched control group of 50 healthy individuals, and analysed for outcome association over a median follow-up duration of 5 years. A subgroup of 30 ARVC patients with normal RA volume (ARVC-N group) was compared with 30 matched controls (Control-N), and the outcome was analysed separately. RA reservoir, conduit, and pump strain were significantly impaired in ARVC vs. control. Similar observations were made in the N-ARVC subgroup. Reservoir strain was associated with an increased risk of atrial arrhythmia (AA) [hazard ratio (HR) 0.88, P < 0.01] and CV events (HR 0.92, P < 0.01). Conduit strain also predicted AA (HR 1.02, P < 0.01), while pump strain predicted CV events (HR 1.09, P = 0.02). Reservoir strain improved the fitness of bivariable models for the association of RV end-diastolic area index, RV fractional area change, and RV global longitudinal strain with CV events. CONCLUSION: ARVC patients display impaired RA strain even when RA volume is normal. Reservoir and pump strain are associated with an increased risk of CV events. Reservoir strain improved model fitness for the association of RVGLS and other echocardiographic parameters with CV events.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Atrial Appendage , Echocardiography , Heart Atria/diagnostic imaging , Humans , Myocardium
17.
ESC Heart Fail ; 9(4): 2207-2214, 2022 08.
Article in English | MEDLINE | ID: mdl-35619238

ABSTRACT

AIMS: Synchronized diaphragmatic stimulation (SDS) modulates intrathoracic and intra-abdominal pressures with favourable effects on cardiac function for patients with a reduced left ventricular ejection fraction (LVEF) and heart failure (HFrEF). VisONE-HF is a first-in-patient, observational study assessing the feasibility and 1 year effects of a novel, minimally invasive SDS device. METHODS AND RESULTS: The SDS system comprises a pulse generator and two laparoscopically delivered, bipolar, active-fixation leads on the inferior diaphragmatic surface. Fifteen symptomatic men with HFrEF and ischaemic heart disease receiving guideline-recommended therapy were enrolled (age 60 [56, 67] years, New York Heart Association class II [53%] /III [47%], LVEF 27 [23, 33] %, QRSd 117 [100, 125] ms, & N terminal pro brain natriuretic peptide [NT-proBNP] 1779 [911, 2,072] pg/mL). Implant success was 100%. Patients were evaluated at 3, 6, and 12 months for device-related or lead-related complications, quality of life (SF-36 QOL), 6 min hall walk distance (6MHWd), and by echocardiography. No implant procedure or SDS-related adverse event occurred, and patients were unaware of diaphragmatic stimulation. By 12 months, left ventricular end-systolic volume decreased (136 [123, 170] mL to 98 [89, 106] mL; P = 0.05), 6MHWd increased (315 [300, 330] m to 340 [315, 368] m; P = 0.004), and SF-36 QOL improved (physical scale 0 [0, 0] to 25 [0, 50], P = 0.006; emotional scale 0 [0, 33] to 33 [33, 67], P = 0.001). Although neither reached statistical significance, LVEF decreased (28 [23, 40]% vs. 34 [29, 38]%; P = ns) and NT-proBNP was lower (1784 [920, 2540] pg/mL vs. 1492 [879, 2028] pg/mL; P = ns). CONCLUSIONS: These data demonstrate the feasibility of laparoscopic implantation and delivery of SDS without raising safety concerns. These encouraging findings should be investigated further in adequately powered randomized trials.


Subject(s)
Heart Failure , Myocardial Ischemia , Humans , Male , Middle Aged , Myocardial Ischemia/complications , Quality of Life , Stroke Volume , Ventricular Function, Left
18.
J Clin Med ; 11(5)2022 Feb 22.
Article in English | MEDLINE | ID: mdl-35268241

ABSTRACT

(1) Background: Physical exercise has been suggested to promote disease progression in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). We aimed to investigate the exercise performance and ventricular function of ARVC patients during follow-up, while taking into account their adherence to exercise restriction recommendations. (2) Methods: This retrospective study included 49 patients (33 male, 67%) who had an exercise test at baseline and after 4.2 ± 1.6 years. Of the 49 ARVC patients, 27 (55%) were athletes, while 22 (45%) were non-athletes. Of the athletes, 12 (44%) continued intensive sports activity (non-adherent), while 15 (56%) stopped intensive physical activity upon recommendation (adherent). The maximum workload in Watts (W), percentage of the target workload (W%), and double product (DP) factor were measured for all patients. (3) Results: The non-adherent cohort had a significant decrease in physical performance (W at baseline vs. follow-up, p = 0.012; W% at baseline vs. follow-up, p = 0.025; DP-factor at baseline vs. follow-up, p = 0.012) over time. Left ventricular (LV) function (LV ejection fraction at baseline vs. follow-up, p = 0.082) showed a decreasing trend in the non-adherent cohort, while the performance of the adherent cohort remained at a similar level. (4) Conclusions: If intensive sports activities are not discontinued, exercise capacity and left ventricular function of athletes with ARVC deteriorates during follow-up. All patients with ARVC need to strictly adhere to the recommendation to cease intense sports activity in order to halt disease progression.

19.
JAMA Cardiol ; 7(5): 494-503, 2022 05 01.
Article in English | MEDLINE | ID: mdl-35353118

ABSTRACT

Importance: Machine learning algorithms enable the automatic classification of cardiovascular diseases based on raw cardiac ultrasound imaging data. However, the utility of machine learning in distinguishing between takotsubo syndrome (TTS) and acute myocardial infarction (AMI) has not been studied. Objectives: To assess the utility of machine learning systems for automatic discrimination of TTS and AMI. Design, Settings, and Participants: This cohort study included clinical data and transthoracic echocardiogram results of patients with AMI from the Zurich Acute Coronary Syndrome Registry and patients with TTS obtained from 7 cardiovascular centers in the International Takotsubo Registry. Data from the validation cohort were obtained from April 2011 to February 2017. Data from the training cohort were obtained from March 2017 to May 2019. Data were analyzed from September 2019 to June 2021. Exposure: Transthoracic echocardiograms of 224 patients with TTS and 224 patients with AMI were analyzed. Main Outcomes and Measures: Area under the receiver operating characteristic curve (AUC), accuracy, sensitivity, and specificity of the machine learning system evaluated on an independent data set and 4 practicing cardiologists for comparison. Echocardiography videos of 228 patients were used in the development and training of a deep learning model. The performance of the automated echocardiogram video analysis method was evaluated on an independent data set consisting of 220 patients. Data were matched according to age, sex, and ST-segment elevation/non-ST-segment elevation (1 patient with AMI for each patient with TTS). Predictions were compared with echocardiographic-based interpretations from 4 practicing cardiologists in terms of sensitivity, specificity, and AUC calculated from confidence scores concerning their binary diagnosis. Results: In this cohort study, apical 2-chamber and 4-chamber echocardiographic views of 110 patients with TTS (mean [SD] age, 68.4 [12.1] years; 103 [90.4%] were female) and 110 patients with AMI (mean [SD] age, 69.1 [12.2] years; 103 [90.4%] were female) from an independent data set were evaluated. This approach achieved a mean (SD) AUC of 0.79 (0.01) with an overall accuracy of 74.8 (0.7%). In comparison, cardiologists achieved a mean (SD) AUC of 0.71 (0.03) and accuracy of 64.4 (3.5%) on the same data set. In a subanalysis based on 61 patients with apical TTS and 56 patients with AMI due to occlusion of the left anterior descending coronary artery, the model achieved a mean (SD) AUC score of 0.84 (0.01) and an accuracy of 78.6 (1.6%), outperforming the 4 practicing cardiologists (mean [SD] AUC, 0.72 [0.02]) and accuracy of 66.9 (2.8%). Conclusions and Relevance: In this cohort study, a real-time system for fully automated interpretation of echocardiogram videos was established and trained to differentiate TTS from AMI. While this system was more accurate than cardiologists in echocardiography-based disease classification, further studies are warranted for clinical application.


Subject(s)
Myocardial Infarction , Takotsubo Cardiomyopathy , Aged , Artificial Intelligence , Cohort Studies , Echocardiography , Female , Humans , Male , Myocardial Infarction/diagnostic imaging , Takotsubo Cardiomyopathy/diagnostic imaging
20.
ESC Heart Fail ; 9(3): 1677-1681, 2022 06.
Article in English | MEDLINE | ID: mdl-35297198

ABSTRACT

Synchronized diaphragmatic stimulation (SDS) is a novel extra-cardiac device-based therapy for symptomatic heart failure with reduced ejection fraction. SDS provides imperceptible chronic stimulation of the diaphragm through a laparoscopically implanted system consisting of an implantable pulse generator and two sensing/stimulating leads affixed to the inferior surface of the diaphragm delivering imperceptible R-wave gaited pulses that alter intrathoracic pressure improving ventricular filling and cardiac output. We describe, in a man with a history of myocardial infarctions resulting in heart failure and persistent New York Heart Association Class III symptoms despite standard therapies, the successful implantation of SDS resulting in improved quality of life, N-terminal pro brain natriuretic peptide, cardiac function, and exercise tolerance through 12 months of follow-up. Randomized trials are now required to validate these findings.


Subject(s)
Heart Failure , Ventricular Dysfunction, Left , Chronic Disease , Diaphragm , Exercise Tolerance/physiology , Heart Failure/complications , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Male , Quality of Life
SELECTION OF CITATIONS
SEARCH DETAIL
...